Function:
The IUC-7X-TXX is an isolated Thermocouple transmitter that provides high isolation
and rugged design for many control applications. Three-way isolation is provided between
the input, the output and the power. The signal isolation takes place through state-of-the-art
optical isolators to ensure high accuracy and repeatability. Special output drive circuitry
allows the IUC-7X-TXX to drive loads of up to 1600 Ohms which makes it ideal for driving
multi instrument loops.
Several standard Thermocouple types and ranges are available that cover
a wide spectrum of temperatures. Special ranges are available upon consultation
with the factory or your representative.
Specifications:
Isolation: Input to Output to Power 1500 VAC (test)
Accuracy/Linearity:+/- 0.1% max., +/- 0.05% typ.
Operating Temperature: -40 Deg.C. to +50 Deg.C.
Temperature Effects: +/-0.5% max., +/-0.2% typ. (for 40 Deg.C. change)